CoolingSystem APC ACRCCoolingSystem APC ACRC
CoolingSystem APC ACRCCoolingSystem APC ACRC
Environmental Devices
UPSCoolingSystem APC ACRCDiesel Generator Deep SEACoolingSystem Tavan SarmaCoolingSystem Uniflair UG40/MP40CoolingSystem Uniflair BREF

CoolingSystem APC ACRC Monitoring

Monitoring Coolinsystem Apc acrc

Performance indicators and parameters of CoolingSystem APC ACRC monitored by Moein are:

Device General Info:

  • Name
  • Address
  • Port Number
  • Hostname
  • Model
  • Vendor
  • Location
  • Serial Number
  • Firmware Version
  • Hardware Revision
  • Manufacturer Date
  • Availability

Group Status:

  • Group Coolant Output
  • Group Coolant Demand
  • Group Air Flow
  • Group Maximum Rack Inlet Temperature
  • Group Minimum Rack Inlet Temperature
  • Active Flow Control System Status
  • Group Cooling Set Point
  • Supply Air Set Point
  • Preferred Fan Speed Setting
  • Fan Speed Control Setting
  • Active Flow Control Bias Setting
  • Group Number Of Cooling Units
  • Group Configuration Type
  • Percentage Of Glycol Mixture
  • Gain Component Of The PID
  • Integral Component Of The PID
  • Derivative Component Of The PID
  • Maximum Desired Fan Speed
  • Number Of Active Flow Controllers
  • Controller Lamp Test Status
  • Altitude Of The Units Above Sea Level

Cooling System APC ACRC Details Monitoring

Unit Status:

  • Cooling Unit Operating Mode
  • Unit Cooling Output
  • Unit Cooling Demand
  • Unit Air Flow
  • Unit Rack Inlet Temperature
  • Unit Supply Air Temperature
  • Unit Return Air Temperature
  • Unit Containment Differential Pressure
  • Unit Air Filter Differential Pressure
  • Unit Average Fan Speed
  • Input Contact State
  • Output Relay State
  • Unit Power Source
  • Fluid Valve Position
  • Fluid Flow
  • Entering Fluid Temperature
  • Leaving Fluid Temperature
  • Leak Sensor State
  • Unit Air Filter Running Duration
  • Unit Fan 1 Running Duration
  • Unit Fan 2 Running Duration
  • Unit Fan 3 Running Duration
  • Unit Fan 4 Running Duration
  • Unit Fan 5 Running Duration
  • Unit Fan 6 Running Duration
  • Unit Fan 7 Running Duration
  • Unit Fan 8 Running Duration
  • Unit Fan Left Power Supply Running Duration
  • Unit Fan Right Power Supply Running Duration
  • Unit Condensate Pump Running Duration
  • DC Power Feed A Left Power Supply Running Duration
  • DC Power Feed A Right Power Supply Running Duration
  • DC Power Feed B Left Power Supply Running Duration
  • DC Power Feed B Right Power Supply Running Duration

Unit Configuration Threshold and Configs:

  • Air Filter Service Interval
  • Air Filter Service Interval Alarm
  • Unit Rack Inlet Air High Temperature Threshold
  • Unit Supply Air High Temperature Threshold
  • Unit Return Air High Temperature Threshold
  • Unit Entering Fluid High Temperature Threshold
  • Cooling Capacity Options Setting
  • Startup Delay
  • Idle On Leak Detection
  • Configured Power Source Of The Unit
  • Normal State Of The Input Contact
  • Normal State Of The Output Relay
  • Source Of Output Relay Change
  • Idle On Cool Failure